On a lighting circuit, method 1 also proves the switching. At a luminaire, operate the switch:

  • Switched off, the loop is broken. The meter reads open circuit — its over-range display, something like >1.999 Ω.
  • Switched back on, the reading comes back.

On two-way switching the reading also changes depending on which switch has made the circuit, because the line now runs through a strapper and back. More cable, more resistance.

Switched on through the near switch 0.07 Ω Switched on through a strapper too 0.25 Ω more cable, more resistance Switched off loop broken >1.999 Ω open circuit Record the highest reading on the circuit, not the first one
One luminaire, three readings. Off proves the switch breaks the line; on proves it makes it; and the strapper route reads higher. The figures are an example from a short circuit — yours will differ.
A reading that jumps about is usually your probe slipping off the terminal mid-test. Re-seat it and test again before you write anything down.

Test yourself on it

The tests are in the members’ area. Get one wrong and it shows you why, and where to revise.

Get access

Get new notes and exam tips from Sparky

About one email a fortnight. Unsubscribe any time. Privacy notice

That was one section. There are 583.

Sparky Study Notes is the whole Level 3 syllabus written up like this: the explanation, the worked example, and where it is in your book. With a video lesson for every part and a practice paper for every exam.

  • 583sections of written notes
  • 35video lessons
  • 1,463practice questions
  • 146diagrams, redrawn
  • 18th Edition
  • Building Regs
  • PAT
  • Fundamental Inspection & Testing
  • Initial Verification
  • Periodic Inspection & Testing
Get access — £100 12 months. One payment. See what’s inside