BS 7671 Part 7 lists the special installations or locations. The first is locations containing a bath or shower. Any room with a bath or shower, en-suites included, is a special location. A sink on its own doesn't count.

BS 7671 · Contents · Part 7 special installations or locations (701 = bath/shower) · p.3

ZONE 0 (inside bath) ZONE 1 ZONE 2 ZONE 2 2.25 m 0.6 m outside the zones: not notifiable* The zones are the same above a shower tray. Without a tray, zone 1 extends 1.2 m from the fixed water outlet.
Anything installed in zones 0, 1 or 2, such as an extractor fan, light or electric shower, is notifiable. *Work outside the zones isn't notifiable, but the room is still covered by Part P. A pull-cord switch fixed to the ceiling outside the zones is fine.

Electrician's Guide to the Building Regs · Figure: extent of the special location in a bath or shower room (600 mm and 2.25 m) · next page after the notifiable table · p.30

Electrician's Guide to the Building Regs · Bathroom zone drawings: bath, shower tray, walk-in shower with no tray · pp.88–89 Electrician's Guide to the Building Regs · Swimming pool zones · p.93

Test yourself on it

The tests are in the members’ area. Get one wrong and it shows you why, and where to revise.

Get access

Get new notes and exam tips from Sparky

About one email a fortnight. Unsubscribe any time. Privacy notice

That was one section. There are 583.

Sparky Study Notes is the whole Level 3 syllabus written up like this: the explanation, the worked example, and where it is in your book. With a video lesson for every part and a practice paper for every exam.

  • 583sections of written notes
  • 35video lessons
  • 1,463practice questions
  • 146diagrams, redrawn
  • 18th Edition
  • Building Regs
  • PAT
  • Fundamental Inspection & Testing
  • Initial Verification
  • Periodic Inspection & Testing
Get access — £100 12 months. One payment. See what’s inside