SPDs and AFDDs on a live consumer unitWhat does a red SPD window mean?

Free from the notes: Sparky’s video on it, the section word for word as members see it, and a PDF to keep.

From Sparky’s full video lesson. Members get the whole lesson on every notes page.

The question at the end: What does a red SPD window mean? The answer is in the notes below.

The notes

Exactly as they are on the site.

Download these notesPDF · free to keep

Take a live split-load board, the same as the one above, wired to a ring final, a cooker circuit and a lighting circuit. Reading it from the main switch outwards:

  • Main switch: the same 100 A on-load isolator as before, with the loose busbars fitted underneath and screwed in.
  • SPD (surge protective device): protects the installation against overvoltage, like a lightning strike. Ours is a Type 2 (T2) plug-in cartridge with a little window: green is fine, red = replace. Where it sits in the board varies by manufacturer.
  • The SPD doesn't disconnect circuits. Pull it out and everything still works. Think of it as a sponge: it soaks up the surge, turns red, and you replace the cartridge.
  • Two RCBOs on the unprotected side. You can tell they're RCBOs from the RCD symbol and the neutral fly leads at the back.
  • The first is a B32, 30 mA AFDD/RCBO: a Type B 32 A breaker, a 30 mA RCD and an arc fault detection device in one. It feeds the ring final (two lines in the top, two neutrals). It does more than a plain RCBO, because it will also detect loose connections (arcing).
  • The second is an empty B6, 30 mA RCBO, ideal for a domestic lighting circuit needing additional protection. Line in the left-hand terminal, neutral in the far terminal.
  • RCD 1 (30 mA Type A) has two CBs, one in use: the cooker circuit. Its neutral goes to RCD 1's neutral bar.
  • RCD 2 has three CBs, one in use: the lighting circuit on a 6 A breaker. Its neutral goes to the third neutral bar. All CPCs go to the earth bar.

SPD · Type 2 cartridge · green window OK, red = replace

Test yourself on it

The tests are in the members’ area. Get one wrong and it shows you why, and where to revise.

Get access

Get new notes and exam tips from Sparky

About one email a fortnight. Unsubscribe any time. Privacy notice

That was one section. There are 583.

Sparky Study Notes is the whole Level 3 syllabus written up like this: the explanation, the worked example, and where it is in your book. With a video lesson for every part and a practice paper for every exam.

  • 583sections of written notes
  • 35video lessons
  • 1,463practice questions
  • 146diagrams, redrawn
  • 18th Edition
  • Building Regs
  • PAT
  • Fundamental Inspection & Testing
  • Initial Verification
  • Periodic Inspection & Testing
Get access — £100 12 months. One payment. See what’s inside