Inside the plug
A good chunk of PAT is opening a plug and knowing what "right" looks like.
| Check | Requirement |
|---|---|
| The plug | Manufactured to BS 1363 |
| The fuse | BS 1362 — a proper cartridge fuse, correctly rated |
| Pin sleeving | Line and neutral pins sleeved. The earth pin is not sleeved |
| Cord grip | Gripping the sheath, not the individual conductors |
| Terminations | Right conductor in the right terminal, tight, no excessive copper showing |
| Earth | Connected — not floating loose in the plug |
And never fix a fuse. Bridging a rewireable fuse with foil at each end, for example, is genuinely dangerous, and exactly what this work exists to catch.
Appendix 6 · plug checks BS 1363 plug · BS 1362 fuse
Fuse ratings
The Code of Practice does not pick a fuse from the appliance’s wattage. Two checks, in this order:
Section 10 · fuse as the manufacturer recommends · p.79 Table 10.6 · fuse against cable CSA · p.80
Free section from Sparky Study Notes. The full Level 3 notes, 1,463 practice questions and the video lessons: sparkystudynotes.co.uk
Test yourself on it
The tests are in the members’ area. Get one wrong and it shows you why, and where to revise.
Get new notes and exam tips from Sparky
About one email a fortnight. Unsubscribe any time. Privacy noticeThat was one section. There are 583.
Sparky Study Notes is the whole Level 3 syllabus written up like this: the explanation, the worked example, and where it is in your book. With a video lesson for every part and a practice paper for every exam.
- 583sections of written notes
- 35video lessons
- 1,463practice questions
- 146diagrams, redrawn
- 18th Edition
- Building Regs
- PAT
- Fundamental Inspection & Testing
- Initial Verification
- Periodic Inspection & Testing