ELV and SELV lightingWhat counts as extra-low voltage?
Free from the notes: Sparky’s video on it, the section word for word as members see it, and a PDF to keep.
The notes
Exactly as they are on the site.
- ELV
- Extra-low voltage: not exceeding 50 V AC or 120 V ripple-free DC. "Ripple-free" means a perfectly smooth DC line, not half-wave humps.
- LV
- Low voltage: above ELV, up to 1000 V AC (1500 V DC). The 230/400 V mains is LV.
- SELV
- Separated extra-low voltage, supplied through a safety isolating transformer, e.g. 230 V in, 12 V (≤ 50 V) out.
- Where you'll see it: under-cabinet and LED strip lighting, track lighting, media walls and garden lighting.
- ELV isn't automatically safe. You still need the right protective measures and must consider the environment.
- Why the grid steps voltage up: for the same power, higher voltage means less current, so less voltage drop over long distances. That allows thinner cables and fewer transformers.
- Transformer types include step-up and step-down (voltage), current, power and isolating.
Free section from Sparky Study Notes. The full Level 3 notes, 1,463 practice questions and the video lessons: sparkystudynotes.co.uk
Test yourself on it
The tests are in the members’ area. Get one wrong and it shows you why, and where to revise.
Get new notes and exam tips from Sparky
About one email a fortnight. Unsubscribe any time. Privacy noticeThat was one section. There are 583.
Sparky Study Notes is the whole Level 3 syllabus written up like this: the explanation, the worked example, and where it is in your book. With a video lesson for every part and a practice paper for every exam.
- 583sections of written notes
- 35video lessons
- 1,463practice questions
- 146diagrams, redrawn
- 18th Edition
- Building Regs
- PAT
- Fundamental Inspection & Testing
- Initial Verification
- Periodic Inspection & Testing